  smartonline 220-240v 1kva 700w on-line double-conversion ups, tower, c14 inlet, db9 serial model number: SUINT1000XL description tripp lite's smartonline SUINT1000XL on-line, double-conversion ups protects critical server, networking and telecommunications equipment from blackouts, voltage fluctuations and transient surges. space-saving upright tower format. large capacity 1000va/700w ups continuously converts incoming ac to dc, then back to perfect sine wave ac output at selectable 220/230/240v ac (+/-2%). removes harmonic distortion, fast electrical impulses, frequency fluctuations and other hard-to-solve power problems not addressed by other ups types. true sine wave output and zero transfer time offers guaranteed compatibility with all equipment types. includes 4 c13 outlets. includes enhanced db9 serial monitoring port for unattended shutdown, remote control and monitoring of ups system and power data. features true on-line, double conversion ups provides pure sine wave ac output at all times maintains continuous operation with zero transfer time through blackouts, voltage fluctuations and surges removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems corrects brownouts and overvoltages from 175-280v at full load. input voltage range extends to 80-280v at 50% load or less 1000va/700w power capacity with 4 c13 outlets iec320-c14 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles standard internal battery set provides 14 min. runtime at half load and 5 min. runtime at full load db9 serial port for network interface poweralert unattended shutdown software and network cable included fault tolerant electronic bypass maintains utility output during a variety of ups fault conditions diagnostic leds optional pdubhv10 bypass pdu enables hot-swappable ups replacement with no disruption to connected equipment 2 c13 to c14 power cables included highlights 1000va on-line, double-conversion, tower ups system maintains sine-wave 220/230/240v +/-2% output during overvoltages to 280v and brownouts as low as 80v (50/60hz auto-sensing) network communications supported via serial port fault-tolerant auto-bypass mode and current monitoring c14 inlet, c13 outlets, 2 c13 to c14 power cables included package includes SUINT1000XL ups system poweralert software cd-rom serial cable 2 iec320 c13-to-c14 jumper cables owner's manual with warranty information 1 / 5
specifications output output volt amp capacity (va) 1000 output kva capacity (kva) 1 output watt capacity (watts) 700 power factor 0.7 crest factor 3:1 nominal output voltage(s) supported 220v; 230v; 240v nominal voltage details 230v default frequency compatibility 50 / 60 hz frequency compatibility details output frequency matches input nominal on startup, defaults to 50 hz on cold-start output voltage regulation (line mode) +/- 2% output voltage regulation (economy line mode) +/- 10% output voltage regulation (battery mode) +/- 2% output receptacles (4) c13 included output power cables includes 2 c13 to c14 power cables hot-swap pdu options pdubhv10 (2u / 8 c13 outlets) output ac waveform (ac mode) sine wave output ac waveform (battery mode) pure sine wave input rated input current (maximum load) 3.7a (220v),3.5a (230v),3.4a (240v) nominal input voltage(s) supported 220v ac; 230v ac; 240v ac ups input connection type c14 inlet ups input connection description iec320-c14 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles input circuit breakers 8a input phase single-phase battery full load runtime (min.) 5 min. (700w) half load runtime (min.) 14 min. (350w) dc system voltage (vdc) 36 2 / 5
battery recharge rate (included batteries) less than 4 hours from 10% to 90% (typical, full load discharge) battery replacement description hot-swappable, user replaceable batteries voltage regulation voltage regulation description online, double-conversion power conditioning overvoltage correction 2% output voltage regulation during overvoltages to 280 undervoltage correction 2% output voltage regulation during undervoltages to 175 severe undervoltage correction 2% output voltage regulation during undervoltages to 80 (under 50% load only) user interface, alerts & controls switches 2 switches control off/on power status and alarm-cancel/self-test operation alarm cancel operation power-fail alarm can be silenced using alarm-cancel switch audible alarm audible alarm indicates ups startup, power-failure, low-battery, overload, ups fault and remote shutdown conditions led indicators 14 leds indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information - includes 4-led meter display for load and battery charge level surge / noise suppression ups ac suppression joule rating 570 ups ac suppression response time instantaneous emi / rfi ac noise suppression yes physical primary form factor tower ups power module dimensions (hwd, in.) 9.5 x 5.5 x 14.4 ups power module dimensions (hwd, cm) 24.1 x 14 x 36.6 ups power module weight (lbs.) 30.8 ups power module weight (kg) 14 ups shipping dimensions (hwd / in.) 12.8 x 9.5 x 19.9 ups shipping dimensions (hwd / cm) 32.5 x 24.1 x 50.5 shipping weight (lbs.) 37.4 shipping weight (kg) 17 cooling method fan ups housing material steel 3 / 5
environmental operating temperature range +32 to +104 degrees fahrenheit / 0 to +40 degrees celsius storage temperature range +5 to +122 degrees fahrenheit / -15 to +50 degrees celsius relative humidity 0 to 95%, non-condensing ac mode btu / hr. (full load) 264.4 ac economy mode btu / hr. (full load) 151.9 battery mode btu / hr. (full load) 387.4 ac mode efficiency rating (100% load) 90% ac economy mode efficiency rating (100% load) 94% audible noise < 45 db at front side 1m communications communications interface db9 serial network monitoring port description supports detailed monitoring of ups and site power conditions; db9 port supports rs232 communications poweralert software included communications cable db9 cabling included line / battery transfer transfer time no transfer time (0 ms.) in online, double-conversion mode low voltage transfer to battery power (setpoint) 175v (100% load), 80v ( <50% load) high voltage transfer to battery power (setpoint) 280 special features cold start (startup in battery mode during a power failure) cold-start operation supported high availability ups features automatic inverter bypass green energy-saving features high efficiency economy mode operation; schedulable daily hours of economy mode operation certifications ups certifications ce ups certification details ce en62040-1-1, en62040-2 class a warranty 4 / 5
product warranty period (worldwide) 2-year limited warranty ? 2015 tripp lite. all rights reserved. all trademarks are the sole property of their respective owners. tripp lite has a policy of continuous improvement. specifications are subject to change without notice. photos may differ slightly from final products. 5 / 5


▲Up To Search▲   

 
Price & Availability of SUINT1000XL

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X